celTYPE CEL LIQUIDS METER (CEL) pdf icon

The liquid meter with turbine flow-rate transducer is used for measuring and metering the liquid volume, in circular under pressure pipelines.

Technical characteristics

Nominal diameter: 20; 25; 32; 40; 50; 65; 80; 100 mm;
Nominal pressure: 16; 25 bar;
Minimal flow-rate Qmin, m3/h: 0,2; 0,32; 0,52; 1,6; 2,72; 4,4; 6,8; 10,8;
Transition flow-rate Qt, m3/h: 0,5; 0,8; 1,3; 6; 10,2; 16,5; 25,5; 40,5;
Maximum flow-rate Qmax, m3/h: 10; 16; 26; 40; 68; 110; 170; 270;
Maximum tolerated error rate: ±2% for the Qmin ... Qt domain; ±1% for the Qt ... Qmax domain;
Maximum length of the connection cable: 50m;
Execution type: normal; protection level IP65;
Climatic execution: N2.


demELECTROMAGNETIC FLOW-RATE DETECTORS (DEM) pdf icon

The devices are designed to measure the flow-rate of normal and/or high corrosive liquids with the electrical conductivity over 200μs/m, in under pressure pipes, full of liquid.

Technical characteristics

Nominal diameters: 10 … 800mm
Nominal pressures: 6; 10; 16; 25 bar
Measurement accuracy: ±1% of the measuring range (together with the electronic adapter)
Power supply: 120; 220; 240 VAC / 50-60Hz


isdFLOW-RATE SIGNALLING DEVICE (ISD) pdf icon

The flow-rate signaler is used to indicate the flowing or to record a pre-established flow in lubrication or cooling circuits of some units, machine tools, technological plants, etc.

Technical characteristics

Nominal diameters: 15; 20; 25; 32; 40; 50; 65; 80; 100 mm
Maximum relative pressure: 2,5; 6; 10 bar
Working fluid: water, mineral oil, petroleum products


damORIFICE PLATES AND NOZZLES (DAM) pdf icon

DAM-57 are devices used for flow-rate measurement in pipes through which single-phase, physically and thermally homogeneous fluids flow. Their volume mass and viscosity is known under the metering conditions.

Technical characteristics

Nominal diameters: 50 … 1000mm
Nominal pressures: 25; 40; 64; 100; 140; 210; 250 bar
Working fluids: gas; liquids; steam


dtiTURBINE FLOW-RATE TRANSDUCER (DTI) pdf icon

This product is a primary element in the measuring loops of volume flow-rate of liquids with maximum temperature of 150°C, through circular pipes under pressure.

Technical characteristics

Nominal diameters: 20 … 100mm
Nominal pressures: 10; 16; 25; 40; 64; 100; 110; 150 bar
Flow-rate range: 0.4 … 270 m3/h
Measurement accuracy: 1% of measured value


drdVARIABLE AREA FLOWMETER FOR FLUIDS (DRD) pdf icon

The device is used only in flow-rate measurement of fluids that flow up a vertical pipe.

Technical characteristics

Nominal diameters: 25; 32; 40; 50; 65; 80; 100 mm
Nominal pressures: 6; 10; 16; 25; 40; 64 bar
Flow-rate range: 0,1 … 40 m3/h
Measurement accuracy:
• 2.5% of full scale if the measured fluid is water;
• 4.5% of full scale for other fluids, using the conversion curves.
Output signal: 2 …10mA; 4 … 20mA
Power supply: 220VAC / 50Hz; 24VDC
Working fluid temperature: 10 … 150°C for liquids; 0 … 300°C for gas